Industrial water-cooled closed circuit cooling tower

Industrial Water Cooling Closed Circuit Cooling Tower Price of China Suppliercustom production for different size of industrial water closed cooling tower with 2 years guarantee Characteristic of  industrial water closed cooling tower1. Excellent Heat Exchange Performancethe cooling tower adopt the technology of t

Featured Products


Industrial Water Cooling Closed Circuit Cooling Tower Price of China Supplier
custom production for different size of industrial water closed cooling tower with 2 years guarantee


Industrial Water Cooling Closed Circuit Cooling Tower



 Characteristic of  industrial water closed cooling tower

1. Excellent Heat Exchange Performance

the cooling tower adopt the technology of the combination of coil and stuffing to avoid the dry spot  and dirt formed on the coils. so the performance of the heat exchanger is dramatically effective. 

2. Convenient Maintenance

the cooling tower is designed with access door and reparing ladder. It is easy for technicains to inspect the working condition of the cooling tower.Technicians can enter into the cooling tower during operation time 

3. Convenient Transportation and Installation

The cooling tower is designed to be standard upper body part and bottom body part,. It is easy for the transportation and installation of the cooling tower

4.Energy Saving

Variable frequency control ( VFC) is an option for flexible adjustment of the number and speed of working cooling fans to ambient temperature changes, the data of which can be preset at a certain figure. During winter season, the spray water stops automatically when ambient temperature drops to a certain level using only a set number of operating fans to satisfy the reduced cooling requirements.


Industrial Water Cooling Closed Circuit Cooling Tower
Industrial Water Cooling Closed Circuit Cooling Tower



 


MODEL

CAPACITY
(M3/h)

FAN

WATER SPRAYING PUMP

INLET/OUTLET DN(MM)

WEIGHT

DIMENSION

QTY

POWER(K/W)

AIR VOLUME PER SET (M3/h)

QTY

POWER
(K/W)

WATER VOLUME PER SET (M3/h)

SHIPPING
(KG)

OPERATIONG
(KG)

LENGTH
(MM)

WIDTH
(MM)

HEIGHT
(MM)
BHX-3030133500011.153DN8023903790192523804220
BHX-4040144500011.153DN10025103910192523804220
BHX-505015.56500011.570DN10027604340192525804220
BHX-606015.57500011.570DN10032905140192529004220
BHX-707017.58700011.570DN10036805530192529004965
BHX-8080244500012.2100DN10042307650377022004220
BHX-9090244500012.2100DN12545107930377022004720
BHX-100100244500012.2100DN12546208040377022004965
BHX-110110334000013150DN125617010170424022004720
BHX-1251253445000131502-DN100651010510424022004965
BHX-1351354345000141802-DN100710011950561022004220
BHX-1501504340000141802-DN100731012160561022004730
BHX-1651654445000141802-DN100759012440561022004965
BHX-180183444500015.52332-DN125892015580745022004220
BHX-200200444500015.52332-DN125933015990745022004720
BHX-225226444500015.52332-DN125955016210745022004965
BHX-2502505445000241804-DN1001165019090930022004720
BHX-2652655445000241804-DN1001235019790930022004965
BHX-2802806445000241804-DN1001249019930930022004965
 

MODEL

CAPACITY
(M3/h)

FAN

WATER SPRAYING PUMP

INLET/OUTLET DN(MM)

WEIGHT

DIMENSION

QTY

POWER
(K/W)

AIR VOLUME PER SET (M3/h)

QTY

POWER
(K/W)

WATER VOLUME PER SET (M3/h)

SHIPPING
(KG)

OPERATIONG
(KG)

LENGTH
(MM)

WIDTH
(MM)

HEIGHT
(MM)
BNX-101211.51800010.5523DN508901660123011503440
BNX-202112.23000010.7528DN5013702480192511503650
BNX-3033134500010.7528DN5019903620192518403840
BNX-4043146000011.145DN8021203790192518404220
BNX-505115.57500011.565DN8024204490247018404220
BNX-606117.58700011.565DN8026904760247018404450
BNX-707017.510000012.284DN10036506080279018404450
BNX-8080246500012.284DN10041507480377018404220
BNX-9090246500012.284DN10046808010377018404450
BNX-100100246500012.284DN12551208450377018404450
BNX-11011025.57500013120DN12553609430377022004220
BNX-12512525.575000131202-DN100598010050377022004450
BNX-13513525.587000141702-DN100623011270484622004350
BNX-15015027.5100000141702-DN100656011590484622004650
BNX-1651653465000141702-DN100785013730561022004350
BNX-18018335.575000141702-DN125845014330561022004650
BNX-20020035.575000141704-DN80918015380604622004650
BNX-22522537.58700015.52304-DN80978017340723022004650
BNX-25025045.575000231204-DN1001086018520745022004650
BNX-26526545.575000241704-DN1001148020880903022004965
BNX-28028045.575000241704-DN1001172021120903022004965



Industrial Water Cooling Closed Circuit Cooling Tower

* Techncial Proposal, CAD Drawings, And Documents Supported 

* Customerization is available. The company has more than 200 technical staff, more than 60 engineers, has obtained more than 100 patent technology. Heng An is dedicated to provide exceptionally customized products to our clients.

After-Sales Service

* Training how to install and commision the machine, training how to operate the machine. 

* Engineers available to service machinery overseas.

* We can offer you the best payment term

* 18 month warranty period


Industrial Water Cooling Closed Circuit Cooling Tower
Industrial Water Cooling Closed Circuit Cooling Tower
The industrial water closed cooling tower can be sperated into two parts for shipment------the upper part and the lower part.  It will be easy for you to assemble it .  The spare parts will be packed by wooden box
Industrial Water Cooling Closed Circuit Cooling Tower

F&Q
1.Q: Your company is a manufacture or trading company?

A: We are a leading cooling tower,evaporative condenser and dry air cooler manufacturer in China since the year of 1975.It is a "famous brand"-Heng An manufacture in China.
2.Q: How do I get repair parts and how long does it take?
A: We have workshop can supply all parts of the product, and 90% of spare parts can be distributed to any place in the world within one week!
3.Q: What if I don't have the professional engineer to install or maintain the product?
A: We could send experience engineers on site to install the product and train your staff for equipment operation and maintenance.

4.Q: How can I choose a suitable model?
    A: As long as you provide the following information, we can help select the model for you.

Application:

(Explanations: Where the cooling towers will be used for?

 e.g. for HAVC system, Air Compressors, Melting Furnaces, etc.)

Water Flow Rate:(Explanations: How many Tons of water required per hour?)
Inlet Water Temp.:(Explanations: Temperature of hot water to be cooled)
Outlet Water Temp.:

(Explanations: Temperature of cooled water, 

usually it shall be at least 3~4 °C higher than the wet-bulb temp.) 

 Wet-bulb Temp.:(Explanations: Highest wet bulb temp. of the location/area or city to install the tower is essential to know to evaluate the size of towers)
Power Supply:

(Explanations: 380V/3 Phases is standard, which we could have

 in stock, but for customized towers, the delivery time could be longer)

 

 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours